Newborn Resuscitaire Neonatal Infant Radiant Warmer

Model NO.: IRW-2000
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: No
Oxygen Cylinder: No
X-ray Cassette: Yes
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Model NO.: IRW-2000
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: No
Oxygen Cylinder: No
X-ray Cassette: Yes
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
 Newborn Resuscitaire Neonatal Infant Radiant Warmer

Features: 
Temperature Control Mode: pre-heating control, servo control & manual control;
Instant Parameter Display: set temp, skin temp, heat power rate;
Built-in APGAR Timer and >37ºC preset function
Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
Tilting Bed and Rotary Radiant Head;
X-ray Cassette Tray under infant bed, examination light of high illuminance;
Use anti-blast quartz infrared tube as radiant heating source.

Specifications
Environment temperature +18ºC~+30ºC
Environment relative humidity 30ºC~75%
Environment air velocity of flow <0.3m/s
Power requirement ≤1000VA
Temperature control model Auto
Temperature control range 25ºC~37ºC
Temperature override mode to N/A
Temperature sensor accuracy ≤0.3ºC
Mattress temperature uniformity ≤2.0ºC
Temperature rise time ≤45min
Heat output indicate 0~100%
Radiant box horizon angle adjust range 0~±90°step-less
Mattress Tray Size 68cm*54cm
Mattress tilt adjust range 0~±10°step-less
Shelf Max.load 2kg
Heater infrared wavelength 1~3μm


Alarms
Power failure alarm
Sensor failure alarm
Over temperature alarm:≤38.0ºC
 Newborn Resuscitaire Neonatal Infant Radiant Warmer

Features: 
Temperature Control Mode: pre-heating control, servo control & manual control;
Instant Parameter Display: set temp, skin temp, heat power rate;
Built-in APGAR Timer and >37ºC preset function
Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
Tilting Bed and Rotary Radiant Head;
X-ray Cassette Tray under infant bed, examination light of high illuminance;
Use anti-blast quartz infrared tube as radiant heating source.

Specifications
Environment temperature +18ºC~+30ºC
Environment relative humidity 30ºC~75%
Environment air velocity of flow <0.3m/s
Power requirement ≤1000VA
Temperature control model Auto
Temperature control range 25ºC~37ºC
Temperature override mode to N/A
Temperature sensor accuracy ≤0.3ºC
Mattress temperature uniformity ≤2.0ºC
Temperature rise time ≤45min
Heat output indicate 0~100%
Radiant box horizon angle adjust range 0~±90°step-less
Mattress Tray Size 68cm*54cm
Mattress tilt adjust range 0~±10°step-less
Shelf Max.load 2kg
Heater infrared wavelength 1~3μm


Alarms
Power failure alarm
Sensor failure alarm
Over temperature alarm:≤38.0ºC