Tylosin Powder antibacterial spectrum similar to erythromycin.Weak effect on bacteria, the mycoplasma genus effect is strong, large ring lactone class is one of the strongest effect on mycoplasma drug.Sensitive of this product can produce drug resistance, staphylococcus aureus, this product is part of the cross and erythromycin resistance phenomenon.This product is mainly used for the prevention and treatment of swine, poultry, mycoplasma disease, such as chicken chronic respiratory disease and infectious sinus cavity inflammation and pig and mycoplasma pneumonia mycoplasma, such as arthritis.Also can be used as pig growth promoting agent. Tylosin Injection For Sheep,Tylosin Phosphate Powder For Poultry,Tylosin Injection,Tylosin Injection For Animal Hebei Kexing Pharmaceutical Co., Ltd. , http://www.kexingpharma.com
Brief introduction:
1. Three modes of control: Manual, skin temperature and mattress temperature
2. Alloyed bracket, fastness
3. Microprocessor based servo controlled temperature system
4. Control panel displayed by VFD
5. Digital skin temperature sensor, the data is exact and stabilizability
6. High sensitivity and untouched detector to inspect mattress temperature
7. Alarm functions for safety include
Power failure, temperature deviation
Temperature probe failure, over temperature
8. APGAR timer to record therapy time
9. Observe light angle can be adjusted + 90º , and the brightness adjusted
10. Heater head can be adjusted + 90º Horizontally
11. Electric infant bed tilt angle is + 10º , transparent protector folded
12. Convenient X-ray cassette under infant bed
13. Electric height adjusted suit for operation
14. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long
15. Alarms are audible and visual
16. A second thermal cut-out function for more safety
17. Skin temperature sensor failure protect function avoid over temperature
Standard configuration
1. Main body (including the radiant source, control system, infant bed, electric lift stand), I. V. Pole, skin sensor, mattress, one drawer, transparent protector, castors
2. Optional parts: Low pressure aspirator; Oxygen supply system, LED phototherapy unit.
Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤ 1000VA
3. Operating condition
An ambient Temperature: 18° C-30° C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Range of Skin Temperature control: 32° C~38° C
5. Temperature control accuracy: ≤ 0.5° C
6. Alarms functions:
A. Over temperature: > 39° C
B. A second thermal cut- out: 40° C
C. Sensor alarm: Skin temperature sensor failure
Mattress temperature sensor failure
Room temperature sensor failure
D. Power failure
7. Mattress temperature uniformity: <2° C
8. Skin temperature sensor accuracy: ≤ 0.3° C
9. Mattress temperature sensor accuracy: ≤ 0.4° C
10. Room temperature sensor accuracy: ≤ 0.3° C
11. Warm-up time: ≤ 30min
12. Height adjustable range: 0-20CM
13. Bed tilt angle: + 10°
14. APGAR timer range: ≤ 24h
15. Heater head horizontal: ± 90°
16. Mattress size: 76CM X 65CM
17. Distance from heater to mattress: 90CM
18. Whole unit size: 70CMX 110CMX 180CM (180-200CM)
19. Castor load: 1pc≤ 200kg 4pcs≤ 800kg
Transport and storage
1. Environment Temperature: -40° C~ +55° C
2. Environment Relative Humidity: ≤ 95%
3. Atmospheric Pressure: 500~1060hPa
Package:
Each unit is packed one case
Size: 114CMX 94CM X 104CM
Gross weight: ≤ 190KG
Â
YSBN-200 medical infant radiant warmer
Brief introduction:
1. Three modes of control: Manual, skin temperature and mattress temperature
2. Alloyed bracket, fastness
3. Microprocessor based servo controlled temperature system
4. Control panel displayed by VFD
5. Digital skin temperature sensor, the data is exact and stabilizability
6. High sensitivity and untouched detector to inspect mattress temperature
7. Alarm functions for safety include
Power failure, temperature deviation
Temperature probe failure, over temperature
8. APGAR timer to record therapy time
9. Observe light angle can be adjusted + 90º , and the brightness adjusted
10. Heater head can be adjusted + 90º Horizontally
11. Electric infant bed tilt angle is + 10º , transparent protector folded
12. Convenient X-ray cassette under infant bed
13. Electric height adjusted suit for operation
14. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long
15. Alarms are audible and visual
16. A second thermal cut-out function for more safety
17. Skin temperature sensor failure protect function avoid over temperature
Standard configuration
1. Main body (including the radiant source, control system, infant bed, electric lift stand), I. V. Pole, skin sensor, mattress, one drawer, transparent protector, castors
2. Optional parts: Low pressure aspirator; Oxygen supply system, LED phototherapy unit.
Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤ 1000VA
3. Operating condition
An ambient Temperature: 18° C-30° C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Range of Skin Temperature control: 32° C~38° C
5. Temperature control accuracy: ≤ 0.5° C
6. Alarms functions:
A. Over temperature: > 39° C
B. A second thermal cut- out: 40° C
C. Sensor alarm: Skin temperature sensor failure
Mattress temperature sensor failure
Room temperature sensor failure
D. Power failure
7. Mattress temperature uniformity: <2° C
8. Skin temperature sensor accuracy: ≤ 0.3° C
9. Mattress temperature sensor accuracy: ≤ 0.4° C
10. Room temperature sensor accuracy: ≤ 0.3° C
11. Warm-up time: ≤ 30min
12. Height adjustable range: 0-20CM
13. Bed tilt angle: + 10°
14. APGAR timer range: ≤ 24h
15. Heater head horizontal: ± 90°
16. Mattress size: 76CM X 65CM
17. Distance from heater to mattress: 90CM
18. Whole unit size: 70CMX 110CMX 180CM (180-200CM)
19. Castor load: 1pc≤ 200kg 4pcs≤ 800kg
Transport and storage
1. Environment Temperature: -40° C~ +55° C
2. Environment Relative Humidity: ≤ 95%
3. Atmospheric Pressure: 500~1060hPa
Package:
Each unit is packed one case
Size: 114CMX 94CM X 104CM
Gross weight: ≤ 190KG
Â
Ysbn-200 Medical Hospital Infant Newborn Baby Neonatal Radiant Warmer
Model NO.: Ysbn-200
Trademark: YSENMED
Transport Package: Wooden Case
Specification: 2120*900*450-750mm
Origin: China
Model NO.: Ysbn-200
Trademark: YSENMED
Transport Package: Wooden Case
Specification: 2120*900*450-750mm
Origin: China
YSBN-200 medical infant radiant warmer