Model NO.: XYB01
-
Type: Blood Pressure Meter
-
Group: Middle-aged and Old
-
Cuff Color: Blue, Black etc.
-
Material of Bladder: PVC or Latex
-
Bussiness Type: Manufacturer
-
Specification: CE ISO13485
-
HS Code: 9018902000
-
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
-
Certification: CE, ISO13485
-
Style: Blood Pressure Monitor
-
Material of Bulb: PVC or Latex
-
Certificatio: ISO, Ce
-
Trademark: Dengyue
-
Origin: Zhejiang
Specifications
Read Aneroid Sphygmomanometer with latex bladder
1.OEM is available
2.High accuracy
3.Sample is available
Contact
Aneroid Sphygmomanometer with stethoscope
Item |
Description |
Measuring range |
0-300mmHg or 20-300mmHg |
Accuracy |
±0.5kPa(±3.75mmHg) |
Gram |
95-145g |
Color |
Black/Blue/Grey |
Guage |
Zinc Alloy |
Bladder |
PVC or Latex |
Bulb |
PVC or Latex |
Package information
Package |
1set/box  50sets/ctn |
Box size |
18.7X10.5X7CM |
Carton size |
55x37x37CM |
GW/NW |
24/25KGS |
User's Manual
A.The product is in compliance with EN1060Non-invasive Sphygmomanometers; B.Operating procedure: Practice  the  following procedure several times to become Familiar with the equipment Before taking your blood to relax And rest for at least 15minutes.This will reduce the error due To physical activity.If you re-right handed.Slip the pressure Cuff over your left arm and extent your left arm palm up. Whether sitting or lying,be sure that your arm rests at the Same level as your heart.Turn the cuff so that the stethoscope Diaphragm (sound head) is on the inside of the arm just above The elbow.This locates it over the large artery near the hollow Of the elbow.(this artery can be also found by feeling for the Pulse of the artery ) Grasp the end of the cuff and pull it snug. Then wrap it around and over your arm.Pressing together with Velcro tape to bind the cuff securely. 2.Inflate the cuff Feel the pulse of the artery with your fingertips to be sure the Heads of the stethoscope is located directly over it.Insert the Earpieces of the stethoscope (adjust by turning earpieces to fit Comfortably in your ears ) Hold the gauge in your left hand or Clip onto the chug on the loop provided for reading.Close the Air-flow  valve  on  the  bulb (turn  clockwise) DO  NOT OVERTIGHTEN.Inflate the cuff by repeatedly squeezing the Bulb with your right hand.Listen to the pulse beat whilst Inflating the cuff.Watch the gauge.When you can no longer Hear the pulse beat,raise the pressure an additional 30mm. 3.Slowly deflate the cuff Slowly open the air-flow valve by turning counter clockwise so That the pressure drops 2-4mmHg with each beat of your heart. (This will usually mean a drop of one to two marks on the gauge Every second) The rate of deflation is important for accurate reading Remember, high pressure of  the cuff has shut of all blood. Flow to the arm.So do not leave it inflated fully any longer than Absolutely necessary. 4.Systolic pressure After opening the air-flow valve,listen carefully for a pulse Beat.The moment you hear the faint rhythmic tapping or Thumping sound of the pulse beat, note tbe reading on the Gauge.This is your systolic(upper)blood pressure. It may be different at first for you to detect the sounds of the Pulse beat.Listen carefully and acquaint yourself with these Unfamiliar sounds.You should also notice the needle on the Gauge "bounce" when your systolic pressure is reached. 5.Diastolic pressure Allow the pressure to continue dropping at the same rate as Before 2-4mmHg per second  Listen carefully with  the Stethoscope  The sounds you hear will change the phases. From the first sharp tagging or thud.They will soften to blowing Or swishing sounds.Watch the falling needle.At the exact Point when you can nolonger hear the sounds, read the gauge, This is your diastolic (lower) blood pressure reading. C  Notice With proper care.Your blood pressure Monitor will provide Many years ofreliable service To insure a well functioning unit, Follow these basic rules. *Pressure gauge should be handled with care,do not drop or Jar Needle should indicate zero when cuff is fully deflated. *Always deflate cuff before storing. *Avoid bitting objects against surface of stethoscope. D  Maintenance Under normal condition, the device is recommended to be Calibrated every two years.Calibration should also be done After repair.Calibration should be carried out at point 50mmHg And 200mmHg. |