Peak shape problem                                    Possible cause Preventive measures / solutions Peak tail Interaction with reactive silanols Ultra-high purity silicon-based (silica gel matrix) stationary phase Add alkaline mobile phase additives (such as TEA) - ultra high purity phase is not required Chelation with metal ions in the stationary phase Ibid. Wrong mobile phase pH (improper mobile phase pH) Reduce the pH of the mobile phase to inhibit silanol ionization Increase buffer concentration Glass frit blocking (screen plate blockage) Inverted column (reverse column) Use a tandem (online) filter Invalid column (column failure) Inverted column (reverse column) Replacement column (column) Dead volume not cleaned (too large) Minimize the number of connectors Use a shorter connecting tube Check that all accessories are tight Split peak Pollution column or injection column inlet (injection) end contamination Remove the guard column ferrule (removing the guard core) and perform analysis - replace the guard column if necessary Backflushing (reverse) analytical column For stubborn residues (strongly retained contaminants), try regeneration (regeneration of the column) Replacement column Glass frit blocking (screen plate blockage) Inverted column (reverse column) Use a tandem (online) filter Sample solvent is not compatible with mobile phase Inject the sample into the mobile phase (dissolve the sample with the mobile phase) Elution of the second component Use sample cleaning before injection (purify sample before injection) Change selectivity by changing the mobile phase or column phase (column phase) Column overload (column overload) Use a higher capacity stationary phase Increase the diameter of the column (increase the inside diameter of the column) Reduce the amount of sample (sample) Tongue peak Formation of channels in the column (channels formed in the column) Replacement column (column) Operate within the recommended pH range of the column (recommended by the column) Column overload (column overload) Inject smaller or more diluted sample solutions (reduced injection volume or further diluted sample) Use a higher capacity stationary phase Sample solvent is not compatible with mobile phase Inject the sample into the mobile phase (dissolve the sample with the mobile phase) Low temperature Increase the temperature of the column (increasing the column temperature)
Pain Relief Patch for Breast
Pain Relief Patch For Breast,Pain Relief Plaster For Breast,Relief For Breast Pain,Pad Relief Patch For Breast Shandong XiJieYiTong International Trade Co.,Ltd. , https://www.xjytmedical.com
                                    Â
[Name] Medical Cold Patch
[Package Dimension] 10 round pieces
The pain relief patch is composed of three layers, namely, backing lining, middle gel and protective film. It is free from pharmacological, immunological or metabolic ingredients.
[Scope of Application] For cold physiotherapy, closed soft tissue only.
[Indications]
The patches give fast acting pain relief for breast hyperplasia, breast fibroids, mastitis, breast agglomera tion, swollen pain.
[How To Use a Patch]
Please follow the Schematic Diagram. One piece, one time.
The curing effect of each piece can last for 6-8 hours.
[Attention]
Do not apply the patch on the problematic skin, such as wounds, eczema, dermatitis,or in the eyes. People allergic to herbs and the pregnant are advised not to use the medication. If swelling or irritation occurs, please stop using and if any of these effects persist or worsen.notify your doctor or pharmacist promptly. Children using the patch must be supervised by adults.
[Storage Conditions]
Store below 30c in a dry place away from heat and direct sunlight.